  1/18 te 1 contactors d 3-pole contactors for motor control, 9 to 95 a utilisation category ac-3 control circuit : a.c. references standard power ratings rated instantaneous basic reference. weight of 3-phase motors operational auxiliary complete with code 50/60 hz in category ac-3 current contacts indicating control (q 55 c) in ac-3 circuit voltage (2) up to fixing, 220v 380v 660v 440v cabling (1) 230v 400v 415v 440v 500v 690v kw kw kw kw kw kw a kg 2.2 4 4 4 5.5 5.5 9 CC lc1-d0900 ii (3) 0.320 1C lc1-d0910 ii 0.320 C1 lc1-d0901 ii 0.320 3 5.5 5.5 5.5 7.5 7.5 12 CC lc1-d1200 ii (3) 0.320 1C lc1-d1210 ii 0.320 C1 lc1-d1201 ii 0.320 47.5991010 18 CC lc1-d1800 ii (3) 0.320 1C lc1-d1810 ii 0.350 C1 lc1-d1801 ii 0.350 5.5 11 11 11 15 15 25 CC lc1-d2500 ii (3) 0.320 1C lc1-d2510 ii 0.505 C1 lc1-d2501 ii 0.505 7.5 15 15 15 18.5 18.5 32 CC lc1-d3200 ii (3) 0.320 1C lc1-d3210 ii 0.525 C1 lc1-d3201 ii 0.525 11 18.5 22 22 22 30 40 11 lc1-d4011 ii 1.150 15 22 25 30 30 33 50 11 lc1-d5011 ii 1.150 18.5 30 37 37 37 37 65 11 lc1-d6511 ii 1.150 22 37 45 45 55 45 80 11 lc1-d8011 ii 1.500 25 45 45 45 55 45 95 (4) 1 1 lc1-d9511 ii 1.500 note : add-on auxiliary contact blocks and modules : see pages 1/32 to 1/43. (1) for lc1-d09 to d32 : clip-on mounting onto 35 mm " rail am1-dp. for lc1-d40 to d95 : clip-on mounting onto 35 mm or 75 mm " rail am1-dl. power terminals : lc1-d09 to d95 protected against direct finger contact. ready-to-tighten terminals. (2) standard control circuit voltages (for other voltages, please consult your regional customer centre). volts c 24 42 48 110 220/230 230 240 380/400 400 415 440 500 660 50 hz b5 d5 e5 f5 m5 p5 u5 q5 v5 n5 r5 s5 y5 60 hz b6 d6 e6 f6 m6 C u6 q6 C C r6 C C 50/60 hz b7 d7 e7 f7 m7 p7 u7 q7 v7 n7 r7 C C (3) 3-pole contactors without auxiliary contact (standard en 50012). (4) 95 a rated operational current in ac-3 up to 400 v. other versions contactors with non-protected power terminals enabling power and control connections to be made using ring type terminals. please consult your regional customer centre. c lc1-d2510 ii dimensions, mounting : pages 1/44 to 1/48 lc1-d9511 ii lc1-d0910 ii http://www..net/ datasheet pdf - http://www..net/
1/19 te 1 lp1-d0910 ii a contactors d 3-pole contactors for motor control, 9 to 80 a utilisation category ac-3 control circuit : d.c. references standard power ratings rated instantaneous basic reference. weight of 3-phase motors operational auxiliary complete with code 50/60 hz in category ac-3 current contacts indicating control (q 55 c) in ac-3 circuit voltage (2) up to fixing, 220v 380v 660v 440v cabling (1) 230v 400v 415v 440v 500v 690v kw kw kw kw kw kw a kg 2.2 4 4 4 5.5 5.5 9 1C lp1-d0910 ii 0.580 C1 lp1-d0901 ii 0.580 3 5.5 5.5 5.5 7.5 7.5 12 1C lp1-d1210 ii 0.580 C1 lp1-d1201 ii 0.580 4 7.5 9 9 10 10 18 1C lp1-d1810 ii 0.600 C1 lp1-d1801 ii 0.600 5.5 11 11 11 15 15 25 1C lp1-d2510 ii 0.850 C1 lp1-d2501 ii 0.850 7.5 15 15 15 18.5 18.5 32 1C lp1-d3210 ii 0.880 C1 lp1-d3201 ii 0.880 11 18.5 22 22 22 30 40 11 lp1-d4011 ii 2.100 15 22 25 30 30 33 50 11 lp1-d5011 ii 2.120 18.5 30 37 37 37 37 65 11 lp1-d6511 ii 2.160 22 37 45 45 55 45 80 11 lp1-d8011 ii 2.220 note : add-on auxiliary contact blocks and modules, see pages 1/32 to 1/43. (1) for lp1-d09 to d25 : clip-on mounting on 35 mm " rail am1-dp. for lp1-d40 to d80 : clip-on mounting on 75 mm " rail am1-dl. power terminals : lp1-d09 to d80 protected against direct finger contact. ready-to-tighten terminals. (2) standard control circuit voltages (for other voltages, please consult your regional customer centre). volts a 12 24 36 48 60 72 110 125 220 250 440 u 0.81.1 uc (3) jd bd cd ed nd sd fd gd md ud rd u 0.71.25 uc (4) jw bw cw ew C sw fw C mw C C (3) lp1-d40 to d80 : 0.851.1 uc. (4) lp1-d40 to d80 : 0.751.2 uc. other versions contactors with non-protected power terminals enabling power and control connections to be made using ring type terminals. please consult your regional customer centre. dimensions, mounting : pages 1/44 to 1/48 lp1-d3210 ii http://www..net/ datasheet pdf - http://www..net/
1/20 te 1 contactors d 3 and 4-pole contactors for heating, lighting, etc., 25 to 125 a utilisation category ac-1 control circuit : a.c. references non inductive loads number instantaneous basic reference. weight maximum operational of poles auxiliary complete with code current contacts indicating control utilisation category ac-1 circuit voltage (2) ( q 55 c) fixing, cabling (1) a n/o n/c kg 25 3 CCC lc1-d0900 ii 0.320 C C or lc1-d1200 ii (3) 0.320 1C lc1-d0910 ii 0.320 1 C or lc1-d1210 ii (3) 0.320 C1 lc1-d0901 ii 0.320 C 1 or lc1-d1201 ii (3) 0.320 4 CCC lc1-d12004 ii 0.320 22 CC lc1-d12008 ii 0.320 32 3 CCC lc1-d1800 ii 0.320 1C lc1-d1810 ii 0.350 C1 lc1-d1801 ii 0.350 40 3 CCC lc1-d2500 ii 0.320 1C lc1-d2510 ii 0.505 C1 lc1-d2501 ii 0.505 4 CCC lc1-d25004 ii 0.505 22 CC lc1-d25008 ii 0.505 50 3 CCC lc1-d3200 ii 0.320 1C lc1-d3210 ii 0.525 C1 lc1-d3201 ii 0.525 60 3 C11 lc1-d4011 ii 1.150 4 CCC lc1-d40004 ii 1.150 22 CC lc1-d40008 ii 1.150 80 3 C11 lc1-d5011 ii 1.150 1 1 or lc1-d6511 ii (3) 1.150 4 CCC lc1-d65004 ii 1.150 22 CC lc1-d65008 ii 1.150 125 3 C11 lc1-d8011 ii 1.500 1 1 or lc1-d9511 ii (3) 1.500 4 CCC lc1-d80004 ii 1.530 22 CC lc1-d80008 ii 1.530 note : add-on auxiliary contact blocks and modules, see pages 1/32 to 1/43. (1) for lc1-d09 to d32 : clip-on mounting on 35 mm " rail am1-dp. for lc1-d40 to d95 : clip-on mounting on 35 mm or 75 mm " rail am1-dl. power terminals : lc1-d09 to d95 protected against direct finger contact. ready-to-tighten terminals. (2) standard control circuit voltages (for other voltages, please consult your regional customer centre). volts c 24 42 48 110 220/230 230 240 380/400 400 415 440 500 660 50 hz b5 d5 e5 f5 m5 p5 u5 q5 v5 n5 r5 s5 y5 60 hz b6 d6 e6 f6 m6 C u6 q6 C C r6 C C 50/60 hz b7 d7 e7 f7 m7 p7 u7 q7 v7 n7 r7 C C (3) selection according to number of operating cycles. lc1-d12004 ii lc1-d65004 ii dimensions, mounting : pages 1/44 to 1/48 lc1-d0910 ii http://www..net/ datasheet pdf - http://www..net/
1/21 te 1 contactors d 3 and 4-pole contactors for heating, lighting, etc., 25 to 125 a utilisation category ac-1 control circuit : d.c. references non inductive loads number instantaneous basic reference. weight maximum operational of poles auxiliary complete with code current contacts indicating control utilisation category ac-1 circuit voltage (2) ( q 55 c) fixing, cabling (1) a n/o n/c kg 25 3 C1C lp1-d0910 ii 0.580 1 C or lp1-d1210 ii (5) 0.580 C1 lp1-d0901 ii 0.580 C 1 or lp1-d1201 ii (5) 0.580 4 CCC lp1-d12004 ii 0.580 22 CC lp1-d12008 ii 0.580 32 3 C1C lp1-d1810 ii 0.600 C1 lp1-d1801 ii 0.600 40 3 C1C lp1-d2510 ii 0.850 C1 lp1-d2501 ii 0.850 4 CCC lp1-d25004 ii 0.850 22 CC lp1-d25008 ii 0.850 50 3 C1C lp1-d3210 ii 0.880 C1 lp1-d3201 ii 0.880 60 3 C11 lp1-d4011 ii 2.100 4 CCC lp1-d40004 ii 2.100 22 CC lp1-d40008 ii 2.100 80 3 C11 lp1-d5011 ii 2.120 1 1 or lp1-d6511 ii (5) 2.160 4 CCC lp1-d65004 ii 2.180 22 CC lp1-d65008 ii 2.180 125 3 C11 lp1-d8011 ii 2.220 4 CCC lp1-d80004 ii 2.250 22 CC lp1-d80008 ii 2.250 note : add-on auxiliary contact blocks and modules, see pages 1/32 to 1/43. (1) for lp1-d12 to d32 : clip-on mounting on 35 mm " rail am1-dp. for lp1-d40 to d80 : clip-on mounting on 75 mm " rail am1-dl. power terminals : lp1-d12 to d80 protected against direct finger contact. ready-to-tighten terminals. (2) standard control circuit voltages (for other voltages, please consult your regional customer centre). volts a 12 24 36 48 60 72 110 125 220 250 440 u 0.81.1 uc (3) jd bd cd ed nd sd fd gd md ud rd u 0.71.25 uc (4) jw bw cw ew C sw fw C mw C C (3) for lp1-d40 to d80 : 0.851.1 uc. (4) for lp1-d40 to d80 : 0.751.2 uc. (5) selection according to number of operating cycles. dimensions, mounting : pages 1/44 to 1/48 lp1-d0910 ii lp1-d3210 ii http://www..net/ datasheet pdf - http://www..net/
1/22 te 1 contactors d 3-pole reversing contactors for motor control, assembled by telemecanique 9 to 95 a (a.c. control circuit) and 9 to 32 a (d.c. control circuit). utilisation category ac-3 references 3-pole reversing contactors horizontally mounted (1) a.c. control circuit standard power ratings rated instantaneous basic reference. weight of 3-phase motors operational auxiliary complete with code 50/60 hz in category ac-3 current contacts indicating control in ac-3 per circuit voltage (2) up to contactor fixing, 440v cabling (3) 220v 380v 660v 230v 400v 415v 440v 500v 690v kw kw kw kw kw kw a n/o n/c kg 2.2 4 4 4 5.5 5.5 9 C1 lc2-d0901 ii ii ii ii ii 0.700 3 5.5 5.5 5.5 7.5 7.5 12 C1 lc2-d1201 ii ii ii ii ii 0.700 4 7.5 9 9 10 10 18 C1 lc2-d1801 ii ii ii ii ii 0.750 5.5 11 11 11 15 15 25 C1 lc2-d2501 ii ii ii ii ii 1.100 7.5 15 15 15 18.5 18.5 32 C1 lc2-d3201 ii ii ii ii ii 1.200 11 18.5 22 22 22 30 40 11 lc2-d4011 ii ii ii ii ii 2.400 15 22 25 30 30 33 50 11 lc2-d5011 ii ii ii ii ii 2.400 18.5 30 37 37 37 37 65 11 lc2-d6511 ii ii ii ii ii 2.400 22 37 45 45 55 45 80 11 lc2-d8011 ii ii ii ii ii 3.200 25 45 45 45 55 45 95 (up to 400v) 1 1 lc2-d9511 ii ii ii ii ii 3.200 d.c. control circuit standard power ratings rated instantaneous basic reference. weight of 3-phase motors operational auxiliary complete with code 50/60 hz in category ac-3 current contacts indicating control in ac-3 per circuit voltage (4) up to contactor fixing, 440v cabling (5) 220v 380v 660v 230v 400v 415v 440v 500v 690v kw kw kw kw kw kw a n/o n/c kg 2.2 4 4 4 5.5 5.5 9 C1 lp2-d0901 ii ii ii ii ii 1.200 3 5.5 5.5 5.5 7.5 7.5 12 C1 lp2-d1201 ii ii ii ii ii 1.200 4 7.5 9 9 10 10 18 C1 lp2-d1801 ii ii ii ii ii 1.270 5.5 11 11 11 15 15 25 C1 lp2-d2501 ii ii ii ii ii 1.750 7.5 15 15 15 18.5 18.5 32 C1 lp2-d3201 ii ii ii ii ii 1.850 accessories (to be ordered separately) auxiliary contact blocks and add-on modules, see pages 1/32 to 1/43. (1) fitted with pre-wired power circuit connections and mechanical interlock, without electrical interlocking. (2) standard control circuit voltages (for other voltages, please consult your regional customer centre). volts c 24 42 48 110 220/230 230 240 380/400 400 415 440 500 660 50 hz b5 d5 e5 f5 m5 p5 u5 q5 v5 n5 r5 s5 y5 60 hz b6 d6 e6 f6 m6 C u6 q6 C C r6 C C 50/60 hz b7 d7 e7 f7 m7 p7 u7 q7 v7 n7 r7 C C (3) for lc2-d09 to d32 : clip-on mounting on 35 mm " rail or screw fixing. for lc2-d40 to d95 : clip-on mounting on 35 mm or 75 mm " rail or screw fixing. power terminals protected against direct finger contact and ready-to-tighten terminals. (4) standard control circuit voltages (for other voltages, please consult your regional customer centre). uc (volts) a 12 24 36 48 60 72 110 125 220 250 440 u 0.8 to 1.1 uc standard coils jd bd cd ed nd sd fd gd md ud rd u 0.7 to 1.25 uc wide range coils jw bw cw ew C sw fw C mw C C (5) clip-on mounting on 35 mm " rail or screw fixing. power terminals protected against direct finger contact. ready-to-tighten terminals. other versions reversing contactors fitted with mechanical interlock, with integral electrical interlocking. please consult your regional customer centre . c or a dimensions, mounting : pages 1/44 to 1/48 lc2-d1201 ii lp2-d0901 ii http://www..net/ datasheet pdf - http://www..net/
1/23 te 1 contactors d 4-pole changeover contactors for distribution circuits, assembled by telemecanique 25 to 125 a (a.c. control circuit) and 25 and 40 a (d.c. control circuit). utilisation category ac-1 references 4-pole changeover contactors, horizontally mounted (1) a.c. control circuit non inductive loads instantaneous basic reference. weight maximum rated auxiliary complete with code operational current contacts indicating control utilisation category ac-1 per circuit voltage ( q < 55 c) contactor fixing, cabling (3) a n/o n/c kg 25 CC lc2-d12004 ii 0.700 40 CC lc2-d25004 ii 1.100 60 CC lc2-d40004 ii 2.400 80 CC lc2-d65004 ii 3.200 125 CC lc2-d80004 ii 3.200 4-pole changeover contactors, horizontally mounted (1) d.c. control circuit non inductive loads instantaneous basic reference. weight maximum rated auxiliary complete with code operational current contacts indicating control utilisation category ac-1 per circuit voltage ( q < 55 c) contactor fixing, cabling (5) a n/o n/c kg 25 CC lp2-d12004 ii 1.200 40 CC lp2-d25004 ii 1.750 accessories (to be ordered separately) auxiliary contact blocks and add-on modules, see pages 1/32 to 1/43. (1) fitted with pre-wired power circuit connections and mechanical interlock, without electrical interlocking. order separately 2 auxiliary contact blocks la1-dn i 1 to obtain electrical interlocking between the 2 contactors (see pages 1/33 to 1/37). (2) standard control circuit voltages (for other voltages, please consult your regional customer centre). volts c 24 42 48 110 220/230 230 240 380/400 400 415 440 500 660 50 hz b5 d5 e5 f5 m5 p5 u5 q5 v5 n5 r5 s5 y5 60 hz b6 d6 e6 f6 m6 C u6 q6 C C r6 C C 50/60 hz b7 d7 e7 f7 m7 p7 u7 q7 v7 n7 r7 C C (3) for lc2-d12 and d25 : clip-on mounting on 35 mm " rail or screw fixing. for lc2-d40 to d80 : clip-on mounting on 35 mm or 75 mm " rail or screw fixing. power terminals protected against direct finger contact. ready-to-tighten terminals. (4) standard control circuit voltages (for other voltages, please consult your regional customer centre). uc (volts) a 12 24 36 48 60 72 110 125 220 250 440 u 0.8 to 1.1 uc standard coils jd bd cd ed nd sd fd gd md ud rd u 0.7 to 1.25 uc wide range coils jw bw cw ew C sw fw C mw C C for other voltages, please consult your customer centre. (5) clip-on mounting on 35 mm " rail or screw fixing. power terminals protected against direct finger contact. ready-to-tighten terminals. other versions reversing contactors fitted with mechanical interlock, with integral electrical interlocking. please consult your regional customer centre . c or a dimensions, mounting : pages 1/44 to 1/48 lc2-d12004 ii http://www..net/ datasheet pdf - http://www..net/
1/24 te 1 a1 a1 a2 a2 1 2 3 4 5 6 1 2 3 4 5 6 l1 l2 l3 u v w a2 a2 a1 a1 1 2 3 4 5 6 3 4 5 6 7 8 1/l1 1/l2 1/l3 l2 1 2 l1 7 8 1n 2/l1 2/l2 2/l3 2n l3 n contactors d 3 and 4-pole contactors components for assembling reversing contactors and changeover contactor pairs (horizontally mounted) , for customer assembly combinations contactors mechanical interlocks set of power connections assembled without with integral 3-pole reversing contactors 4-pole changeover using 2 identical electrical interlocking electrical interlocking contactor pairs contactors (2 n/c contacts) horizontally mounted, type : lc1-d09 la9-d09978 la9-d0902 la9-d1269 la9-d1270 lc1-d12 la9-d1869 la9-d2570 lc1-d18 la9-d2569 lc1-d25 la9-d3269 lc1-d32 lp1-d09 lp1-d12 lp1-d18 lp1-d25 lp1-d32 lc1-d40 la9-d50978 la9-d4002 la9-d6569 la9-d6570 lc1-d50 lc1-d65 lp1-d40 lp1-d50 lp1-d65 lc1-d80 la9-d8069 la9-d8070 lc1-d95 lp1-d80 la9-d80978 la9-d8002 la9-d8069 la9-d8070 http://www..net/ datasheet pdf - http://www..net/
1/25 te 1 c or a contactors d 3 and 4-pole contactors components for assembling reversing contactors and changeover contactor pairs (horizontally mounted) , for customer assembly references component parts (including mechanical interlock with integral electrical interlocking) with set of power connections mechanical interlock 2 identical reference weight kit reference weight contactors (1) kg kg for assembly of 3-pole reversing contactors for motor control lc1/lp1-d09 iiii la9-d1269 0.015 la9-d0902 0.060 lc1/lp1-d12 iiii lc1/lp1-d18 iiii la9-d1869 0.030 la9-d0902 0.060 lc1/lp1-d25 iiii la9-d2569 0.030 la9-d0902 0.060 lc1/lp1-d32 iiii la9-d3269 0.040 la9-d0902 0.060 lc1/lp1-d4011 ii la9-d6569 0.290 la9-d4002 0.170 lc1/lp1-d5011 ii lc1/lp1-d6511 ii lc1-d8011 ii la9-d8069 0.490 la9-d4002 0.170 lp1-d8011 ii la9-d8069 0.490 la9-d8002 0.170 lc1-d9511 ii la9-d8069 0.490 la9-d4002 0.170 for assembly of 4-pole changeover contactor pairs for distribution (3-phase + neutral distribution system) lc1/lp1-d12004 ii la9-d1270 0.010 la9-d0902 0.060 lc1/lp1-d25004 ii la9-d2570 0.020 la9-d0902 0.060 lc1/lp1-d40004 ii la9-d6570 0.150 la9-d4002 0.170 lc1/lp1-d65004 ii lc1-d80004 ii la9-d8070 0.280 la9-d4002 0.170 lp1-d80004 ii la9-d8070 0.280 la9-d8002 0.170 component parts (including mechanical interlock, without electrical interlocking) for assembly of 3-pole reversing contactors for motor control lc1/lp1-d0901 ii la9-d1269 0.015 la9-d09978 0.030 lc1/lp1-d1201 ii lc1/lp1-d1801 ii la9-d1869 0.030 la9-d09978 0.030 lc1/lp1-d2501 ii la9-d2569 0.030 la9-d09978 0.030 lc1/lp1-d3201 ii la9-d3269 0.040 la9-d09978 0.030 lc1/lp1-d4011 ii la9-d6569 0.290 la9-d50978 0.155 lc1/lp1-d5011 ii lc1/lp1-d6511 ii lc1-d8011 ii la9-d8069 0.490 la9-d50978 0.155 lp1-d8011 ii la9-d8069 0.490 la9-d80978 0.180 lc1-d9511 ii la9-d8069 0.490 la9-d50978 0.155 for assembly of 4-pole changeover contactor pairs for distribution (3-phase + neutral distribution system) (2) lc1/lp1-d12004 ii la9-d1270 0.010 la9-d09978 0.030 lc1/lp1-d25004 ii la9-d2570 0.020 la9-d09978 0.030 lc1/lp1-d40004 ii la9-d6570 0.150 la9-d50978 0.155 lc1/lp1-d65004 ii lc1-d80004 ii la9-d8070 0.280 la9-d50978 0.155 lp1-d80004 ii la9-d8070 0.280 la9-d80978 0.180 (1) to order the 2 contactors : see pages 1/18 to 1/21. (2) order 2 contact blocks la1-dn i 1 to obtain electrical interlocking. see pages 1/33 to 1/37. illustrations : page 1/24 http://www..net/ datasheet pdf - http://www..net/
1/26 te 1 thermal overload relays d 3-pole thermal overload relays (class 10 a) adjustable from 0.1 to 93 a, for motor protection references thermal overload relays to be used with fuses thermal overload relays - compensated with manual or automatic reset, - relay trip indicator, - for a.c. or d.c. relay fuses to be used for direct reference weight setting with selected relay mounting range type beneath contactor am gg (bs88) lc1, lp1 aa a kg class 10 a (1) 0.100.16 0.25 2 d09d32 lr2-d1301 0.165 0.160.25 0.5 2 d09d32 lr2-d1302 0.165 0.250.40 1 2 d09d32 lr2-d1303 0.165 0.400.63 1 4 d09d32 lr2-d1304 0.165 0.631 2 4 d09d32 lr2-d1305 0.165 11.6 2 6 d09d32 lr2-d1306 0.165 1.62.5 4 10 d09d32 lr2-d1307 0.165 2.54 6 16 d09d32 lr2-d1308 0.165 46 8 16 d09d32 lr2-d1310 0.165 5.58 12 20 d09d32 lr2-d1312 0.165 710 12 20 d09d32 lr2-d1314 0.165 913 16 25 d12d32 lr2-d1316 0.165 1218 20 32 d18d32 lr2-d1321 0.165 1725 25 50 d25 and d32 lr2-d1322 0.165 2332 40 63 d25 and d32 lr2-d2353 0.320 30...40 40 80 d32 lr2-d2355 0.320 1725 25 50 d40d95 lr2-d3322 0.510 2332 40 63 d40d95 lr2-d3353 0.510 3040 40 80 d40d95 lr2-d3355 0.510 3750 63 100 d50d95 lr2-d3357 0.510 4865 63 100 d50d95 lr2-d3359 0.510 5570 80 125 d65d95 lr2-d3361 0.510 6380 80 125 d80 and d95 lr2-d3363 0.510 8093 100 160 d95 lr2-d3365 0.510 3-pole thermal overload relays for use with unbalanced loads class 10 a : change the prefix in the references above from lr2 to lr3 . example : lr3-d1301 . (1) standard iec 947-4 specifies a tripping time for 7.2 times the setting current i r : class 10 a : between 2 and 10 seconds. other versions thermal overload relays - for distribution circuits, - with flat terminals for ring type connectors (except lr2-d3365). please consult your regional customer centre. lr2, lr3-d1 independent mounting on 50 mm centres independent mounting on 110 mm centres remote trip or electrical reset or on rail am1-dp200 or de200 am1-dp200 am1-de200 d 2 9.5 (1) can be mounted on rh or lh (1) + 5 mm for lr2-d15 ii side of relays lr2, lr3-d1 lr2-d33 ii lr2-d23 ii lr2-d13 ii 98 43,5 d 79 la7-d1064 4 50/60(1) 8 17 2x4,5 35 = = 45 108 125 la7-d1064 110 = = 46 = = 2x6,5 dx1-ap25 96 34 la7-d03 (1) http://www..net/ datasheet pdf - http://www..net/
1/27 te 1 thermal overload relays d 3-pole thermal overload relays (class 20) adjustable from 0.1 to 93 a, for motor protection references thermal overload relays to be used with fuses thermal overload relays - compensated with manual or automatic reset, - relay trip indicator, - for a.c. or d.c. relay fuses to be used for direct reference weight setting with selected relay mounting range type beneath contactor am gg (bs88) lc1, lp1 aa a kg class 20 (1) 2.54 6 16 d09d32 lr2-d1508 0.190 46 8 16 d09d32 lr2-d1510 0.190 5.58 12 20 d09d32 lr2-d1512 0.190 710 16 25 d09d32 lr2-d1514 0.190 913 16 25 d12d32 lr2-d1516 0.190 1218 25 40 d18d32 lr2-d1521 0.190 1725 32 50 d25 and d32 lr2-d1522 0.190 2332 40 63 d25 and d32 lr2-d2553 0.345 1725 32 50 d40d95 lr2-d3522 0.535 2332 40 63 d40d95 lr2-d3553 0.535 3040 50 80 d40d95 lr2-d3555 0.535 3750 63 100 d50d95 lr2-d3557 0.535 4865 80 100 d50d95 lr2-d3559 0.535 5570 100 125 d65d95 lr2-d3561 0.535 6380 100 125 d80 and d95 lr2-d3563 0.535 (1) standard iec 947-4 specifies a tripping time for 7.2 times the setting current i r : class 20 : between 6 and 20 seconds. other versions thermal overload relays - for distribution circuits, - with flat terminals for ring type connectors. please consult your regional customer centre. lr2, lr3-d2 independent mounting on 50 mm centres independent mounting on 110 mm centres remote trip or electrical reset device or on rail am1-dp200 or de200 am1-dp200 am1-de200 (1) can be mounted on rh or lh d 2 9.5 side of relays lr2, lr3-d2 lr2, lr3-d3 independent mounting on 50 mm centres independent mounting on 110 mm centres remote trip or electrical reset device or on rail am1-dp200 or de200 am1-dp200 am1-de200 (1) can be mounted on rh or lh side d 2 9.5 of relays lr2-d, lr3-d3 lr2-d15 ii ii ii ii ii lr2-d25 ii ii ii ii ii lr2-d35 ii ii ii ii ii 96 108 la7-d2064 110 = = 57 = = 2x6,5 dx1-ap26 125 98 43,5 d 90 la7-d2064 3 50/60 13 22 2x4,5 40 = = 55 29 la7-d03 (1) 121 100 2x4,5 la7-d3064 51,5 d 75/87 2 50 75 = = 23,5 32 126 131 la7-d3064 75 = = 40 == 110 la7-d902 3x6,5 119 21 la7-d03 (1) http://www..net/ datasheet pdf - http://www..net/
1/28 te 1 dx1-ap25 la7-d901 dx1-ap26 la7-d2064 la7-d902 la7-d03 la7-d03 la7-d1064 la7-d3064 lr2-d1 lr3-d1 lr2-d2 lr3-d2 lr2-d3 lr3-d3 r r la7-d1020 za2-bz13 za2-ba639 la7-d1020 za2-bz13 za2-bl432 la7-d305 lr2-d lr2-d http://www..net/ datasheet pdf - http://www..net/
1/29 te 1 thermal overload relays d 3-pole thermal overload relays adjustable from 0.1 to 93 a references accessories (to be ordered separately) description for use on sold in unit weight overload relays lots of reference kg terminal blocks (1) lr2-d1 1 la7-d1064 0.100 for clip-on mounting on lr3-d1 35 mm rail (am1-dp200) lr2-d2 1 la7-d2064 0.120 or screw fixing. lr3-d2 see pages 1/26 and 1/27 lr2-d3 1 la7-d3064 (2) 0.205 for fixing centres lr3-d3 power terminals adaptor lr2-d1 1 la7-d1058 0.080 for mounting an lr i -d13 lr3-d1 overload relay beneath an lc1-d40, d50 or d65 contactor mounting plates (3) lr2-d1 10 dx1-ap25 0.065 for screw fixing lr3-d1 on 110 mm centres lr2-d2 10 dx1-ap26 0.082 lr3-d2 lr2-d3 1 la7-d902 0.130 lr3-d3 marker holder lr2-d 100 la7-d903 0.001 snap-in lr3-d bag of 400 labels C 1 la9-d91 0.001 (blank, self-adhesive) 7 x 16 mm locking device lr2-d 10 la7-d901 0.005 for stop button lr3-d remote tripping and lr2-d 1 la7-d03 i (5) 0.090 electrical reset device (4) lr3-d remote control reset function by flexible cable lr2-d 1 la7-d305 0.075 (length = 0.5 m) lr3-d stop and/or reset function for fitting, remove the terminal protection shrouds and order the following 3 products : adaptor lr2-d 1 la7-d1020 0.005 for door mounted operator lr3-d rod (snap-off end to obtain required lr2-d 10 za2-bz13 0.100 length between 17 and 120 mm) lr3-d operating head lr2-d 1 za2-b iiii (6) 0.012 for spring return pushbutton lr3-d (1) terminal blocks are supplied with terminals protected against direct finger contact. ready-to-tighten screws. (2) with terminals for ring type connectors, the reference becomes la7-d30646. (3) remember to order the terminal block corresponding to the overload relay size. (4) the time for which the coil of remote tripping and electrical resetting device la7-d03 can remain energised depends on its rest time : 1 s pulse duration with 9 s rest time ; 5 s pulse duration with 30 s rest time ; 10 s pulse duration with 90 s rest time ; maximum pulse duration of 20 s with a rest time of 300 s. minimum impulse time : 200 ms. (5) reference to be completed by adding the coil voltage code. standard control circuit voltages (for other voltages, please consult your regional customer centre). volts c 12 24 48 96 110 220/230 380/400 415/440 50/60 hz C b e C f m q n consumption, inrush and sealed : < 100 va volts a j beddfmC C consumption, inrush and sealed : < 100 w. (6) reference to be completed, please refer to chapter 5. la7-d1020 la7-d305 adaptor for door mounted operator reset by flexible cable mounting with cable straight mounting with cable bent stop reset c : adjustable from 17 to 120 mm c : up to 550 mm e : up to 20 mm e : up to 20 mm illustrations : page 1/28 la7-d305 c e m10x1 e c 10 la7-d1020 http://www..net/ datasheet pdf - http://www..net/
1/30 te 1 setting the relay i lift the transparent cover 1 to gain access to the settings and controls. i adjustment is achieved by turning dial 2 which is graduated directly in amperes. i the setting can be locked by sealing 3 of the cover. stop function 5 stop locking i the stop function is obtained by pressing the red stop button 5 . i pressing the stop button : - actuates the n/c contact, - does not affect the n/o contact. i the stop button can be locked by fitting a u clip (ref. la7-d901 ). with the cover folded down, the device is locked. thermal overload relays d 3-pole thermal overload relays adjustable from 0.1 to 93 a scheme, setting-up scheme lr2-d lr3-d setting-up the special functions of lr2-d and lr3-d thermal overload relays 1 3 5 2 4 6 97 98 96 95 test reset auto. man. { stop references : pages 1/26 to 1/29 8 a 6 reset stop test 98 97 95 96 no nc m a u t o 5,5 7 lr2 d 13 7 5 4 2 1 6 3 a u t o reset et a u t o stop reset a u t o test ?anual-automatic?selection 4 manual reset automatic reset i after having lifted the transparent cover, the type of reset operation can be selected by turning the blue reset selector 4 : - turn to the left for manual reset, - push and turn to the right for automatic reset. the selector is then held in the automatic position and is released by turning the selector to the left (return to manual operation). i with the cover folded down, the selector is locked. i manual resetting of the relay is achieved by pressing the blue reset button. test function 6 test trip indicator i the test function is obtained by pressing the red test button 6 with a screwdriver. i operation of the test button simulates tripping of the relay and : - actuates both n/o and n/c contacts, - actuates the trip indicator 7 . reset a u t o http://www..net/ datasheet pdf - http://www..net/
1/31 te 1 thermal overload relays d 3-pole thermal overload relays adjustable from 0.1 to 93 a dimensions lr2, lr3-d1 direct mounting beneath contactors lc1-d09 to d32, lp1-d09 to d32 and lp4-d12 am1-dp200 am1-de200 d 2 9.5 b (1) c e g lc1-d09, d12, d18 81 98 50 0 lc1-d25 86 108 55 10.7 lc1-d32 86 109 55 8.1 lp1-d09, d12, d18 81 133 50 0 lp1-d25 86 152 55 10.7 lp1-d32 86 153 55 8.1 lp4-d12 81 98 50 0 (1) + 5 mm for lr2-d15 ii lr2, lr3-d2 direct mounting beneath contactors lc1-d25 and d32, lp1-d25 and d32 am1-dp200 am1-de200 d 2 9.5 bce g lc1-d25 97.5 98 60 1.5 lc1-d32 97.5 98 60 0.5 lp1-d25 97.5 155 60 1.5 lp1-d32 97.5 155 60 0.5 lr2, lr3-d3 direct mounting beneath contactors lc1-d40 to d95 and lp1-d40 to d80 am1-dl201 am1-dl200 d7 17 b c e g (3p) g (4p) lc1-d40 111 119 72.4 4.5 13 lc1-d50 111 119 72.4 4.5 C lc1-d65 111 119 72.4 4.5 13 lc1-d80 115.5 124 76.9 9.5 22 lc1-d95 115.5 124 76.9 9.5 C lp1-d40 111 176 72.4 4.5 13 lp1-d50 111 176 72.4 4.5 C lp1-d65 111 176 72.4 4.5 13 lp1-d80 115.5 179.4 76.9 9.5 22 b 92 c d 47(1) 8 17 44 g e b 92 c d 59 13 22 54 g e b 109 c d 54 21 30 70 g e 4 references : pages 1/26 and 1/27 http://www..net/ datasheet pdf - http://www..net/
1/32 te 1 la1-dx, dy, dz la1-dn, dc la1-dn la8-dn lc1-d09, d12, d18 la8-dn lc1-d25, d32 lc1-d40, d50, d65, d80, d95 la1-dn10, dn01 la3-dr la2-dt, ds la6-dk http://www..net/ datasheet pdf - http://www..net/
1/33 te 1 contactors d 3 and 4-pole contactors, reversing and changeover contactors auxiliary contact blocks and accessories control circuit : a.c. references instantaneous auxiliary contact blocks (1) for use in normal operating environments number max. number of blocks per contactor composition reference weight of clip-on mounting contacts front side kg 1 1 (d25 and d32) C C C 1 C la1-dn10 0.020 or 2 (d40d95) C1 la1-dn01 0.020 2 1 (d09d95) C C C 1 1 la1-dn11 0.030 2C la1-dn20 0.030 C2 la1-dn02 0.030 C 2 (d09d95) C C 1 1 la8-dn11 0.030 2C la8-dn20 0.030 4 1 (d09d95) C C C 2 2 la1-dn22 0.050 13 la1-dn13 0.050 4C la1-dn40 0.050 C4 la1-dn04 0.050 31 la1-dn31 0.050 2 2 (2) la1-dc22 0.050 with terminal referencing conforming to standard en 50012 2 1 (d0910d3210) C C C 1 1 la1-dn11m 0.030 1 (d0900d3200) C C C 1 1 la1-dn11p 0.030 1 (d40d95) C C C 1 1 la1-dn11g 0.030 4 1 (d0910d3210) C C C 2 2 la1-dn22m 0.050 1 (d0900d3200) C C C 2 2 la1-dn22p 0.050 1 (d40d95) C C C 2 2 la1-dn22g 0.050 instantaneous auxiliary contact blocks with dust and damp protected contacts (1) for use in harsh industrial environments 2 1 (d09d95) C 2 C C C la1-dx20 0.040 C 2 (3)C C la1-dy20 0.040 4 1 (d09d95) C 2 C 2 C la1-dz40 0.050 2C11 la1-dz31 0.060 (1) maximum mounting capacity, depending on type of coil. device coil operation maximum number of add-on blocks type type guaranteed clip-on mounting from front side lc1-d 50 or 60 hz 0.81.1 uc 1 + 2 50/60 hz 0.81.1 uc 1 or 2 0.851.1 uc 1 + 2 (2) including 1 n/o and 1 n/c make before break. (3) device fitted with 4 terminals for earth screen continuity. illustrations : page 1/32 http://www..net/ datasheet pdf - http://www..net/
1/34 te 1 la3-dr la2-dt, ds la6-dk lc1-d09, d12, d18 lc1-d25, d32 lc1-d40, d50, d65, d80, d95 la1-dx, dy, dz la1-dn, dc la1-dn la1-dn10, dn01 la8-dn la8-dn http://www..net/ datasheet pdf - http://www..net/
1/35 te 1 contactors d 3 and 4-pole contactors, reversing and changeover contactors auxiliary contact blocks and accessories control circuit : a.c. references time delay auxiliary contact blocks (1) number maximum number of time delay reference weight of blocks per contactor type setting contacts front clip-on mounting range kg 1 n/o 1 (d09d95) on-delay 0.13 s (2) la2-dt0 0.060 + 1 n/c 0.130 s la2-dt2 0.060 10180 s la2-dt4 0.060 130 s (3) la2-ds2 0.060 off-delay 0.13 s (2) la3-dr0 0.060 0.130 s la3-dr2 0.060 10180 s la3-dr4 0.060 mechanical latch blocks (1) unlatching clip-on basic reference. weight control front mounting to be completed (4) kg manual lc1-d09d65 la6-dk10 i i i i i 0.070 or electric lc1-d80d95 la6-dk20 i i i i i 0.090 (1) maximum mounting capacity, depending on type of coil. device coil operation maximum number of add-on blocks type type guaranteed clip-on mounting from front side lc1-d 50 or 60 hz 0.81.1 uc 1 + 2 50/60 hz 0.81.1 uc 1 or 2 0.851.1 uc 1 + 2 (2) with extended scale from 0.1 to 0.6 s. (3) with switching time of 40 ms 15 ms between opening of the n/c contact and closing of the n/o contact. (4) standard control circuit voltages (for other voltages, please consult your regional customer centre). volts c or a 12 24 32/36 42/48 60/72 100 110/127 220/240 255/277 380/415 code j b c e en k f m u q illustrations : page 1/34 http://www..net/ datasheet pdf - http://www..net/
1/36 te 1 la1-dx, dy, dz la3-dr la2-dt, ds la1-dn, dc la1-dn la6-dk la1-dn10 la1-dn01 lp1-d40, d50, d65, d80 lp1-d25, d32 lp1-d09, d12, d18 la8-dn la8-dn http://www..net/ datasheet pdf - http://www..net/
1/37 te 1 contactors d 3 and 4-pole contactors, reversing and changeover contactors auxiliary contact blocks and accessories control circuit : d.c. references instantaneous auxiliary contact blocks (1) for use in normal operating environments number max. number of blocks per contactor composition reference weight of clip-on mounting contacts front side kg 1 1 (d25 and d32) C C C 1 C la1-dn10 0.020 2 (d40d80) C 1 la1-dn01 0.020 2 1 (d09d80) C C C 1 1 la1-dn11 0.030 2C la1-dn20 0.030 C2 la1-dn02 0.030 2 (d09d32) C C C 1 1 la8-dn11 0.030 2C la8-dn20 0.030 4 1 (d09d80) C C C 2 2 la1-dn22 0.050 13 la1-dn13 0.050 4C la1-dn40 0.050 C4 la1-dn04 0.050 31 la1-dn31 0.050 2 2 (2) la1-dc22 0.050 instantaneous auxiliary contact blocks with dust and damp protected contacts (1) for use in harsh industrial environments 2 1 (d09d80) C 2 C C C la1-dx20 0.040 2 2 (3)C C la1-dy20 0.040 4 1 (d09d80) C 2 C 2 C la1-dz40 0.050 2C11 la1-dz31 0.060 time delay auxiliary contact blocks (1) number max. number of blocks per contactor time delay reference weight of clip-on mounting type setting contacts front side range(s) kg 1 n/o 1 (d09d80) C on 0.13 (4) la2-dt0 0.060 + delay 1 n/c 0.130 la2-dt2 0.060 10180 la2-dt4 0.060 130 (5) la2-ds2 0.060 off 0.13 (4) la3-dr0 0.060 delay 0.130 la3-dr2 0.060 10180 la3-dr4 0.060 mechanical latch blocks (manual or electric unlatching control) front clip-on basic reference. weight mounting to be completed (6) kg lp1-d09d65 la6-dk10 i i i i i 0.070 lp1-d80 la6-dk20 i i i i i 0.090 (1) either of the following may be fitted, as required: 2 side-mounting contact blocks or 1 front mounting contact block. (2) including 1 n/o + 1 n/c make before break. (3) device fitted with 4 terminals for earth screen continuity. (4) with extended scale from 0.1 to 0.6 s. (5) with switching time of 40 ms 15 ms between opening of the n/c contact and closing of the n/o contact. (6) standard control circuit voltages (for other voltages, please consult your regional customer centre). volts c or a 12 24 32/36 42/48 60/72 100 110/127 220/240 255/277 380/415 code j b c e en k f m u q illustrations : page 1/36 http://www..net/ datasheet pdf - http://www..net/
1/38 te 1 lc1-d09, d12, d18 lc1-d25, d32 lc1-d40, d50, d65, d80, d95 la4-dr la4-dt la4-df la4-dl la4-dw la4-dm la4-dv lp1-d40, d50, d65, d80 lp1-d25, d32 lp1-d09, d12, d18 la4-dt la4-df la4-dl la4-dm la4-dv http://www..net/ datasheet pdf - http://www..net/
1/39 te 1 contactors d 3 and 4-pole contactors, reversing and changeover contactors accessories references electronic serial timer modules (1) operational voltage (2) time delay reference weight c lc1- a lp1- 24250 v 100250 v 24250 v kg on-delay type d09d32 d40d95 d09d32 0.12 s la4-dt0u 0.040 1.530 s la4-dt2u 0.040 25500 s la4-dt4u 0.040 off-delay type d09d18 d25d95 C 0.12 s la4-dr0u 0.050 1.530 s la4-dr2u 0.050 25500 s la4-dr4u 0.050 interface modules (1) operational voltage supply reference weight c lc1- a lp1- voltage 24250 v 100250 v 380415 v 24250 v e1-e2 ( a )kg relay interface C C d09d95 C 24 v la4-dfbq 0.055 d09d95 C C d09d32 24 v la4-dfb 0.050 48 v la4-dfe 0.050 relay interface with manual override switch (output forced on) d09d95 C C d09d32 24 v la4-dlb 0.045 48 v la4-dle 0.045 solid state interface d09d32 d40d95 C C 24 v la4-dwb 0.045 auto-man-stop control modules (1) for local override operation tests with 2-position auto-man switch and o-i switch operational voltage reference weight c lc1- a lp1- 24100 v 100250 v 24100 v 100250 v kg d09d95 C d09d32 C la4-dmk 0.040 C d09d95 C d09d32 la4-dmu 0.040 indicators (contactor state) red led for mounting on contactors supply sold in unit weight lc1 and lp1 voltage ( c and a ) lots of reference kg clips into 1272 v 5 la4-dve 0.010 legend plate location on all contactor sizes 72250 v 5 la4-dvm 0.010 250440 v 5 la4-dvr 0.010 (1) mounted at top on terminals a1 and a2 (screw fixing). (2) for 24 v operation, the contactor must be fitted with a 21 v coil (code z). see pages 1/49 to 1/52. illustrations : page 1/38 http://www..net/ datasheet pdf - http://www..net/
1/40 te 1 lc1-d09, d12, d18 la4-d l 1 lc1-d25, d32 lc1-d40, d50, d65, d80, d95 lp1-d40, d50, d65, d80 lp1-d25, d32 lp1-d09, d12, d18 la4-d l 2 la4-d l 1 la4-d l 2 la4-d l 3 http://www..net/ datasheet pdf - http://www..net/
1/41 te 1 contactors d 3 and 4-pole contactors, reversing and changeover contactors accessories references coil suppressor modules rc circuits (resistor-capacitor) (1) mounted at top for use with contactor (2) reference weight of contactor on rating type coil terminals a1 and a2 c lc1- a lp1- vv kg clip-on fixing and electrical d09d32 2448 C la4-da1e 0.012 connection. fitting of an input 50127 C la4-da1g 0.012 module is still possible. 110240 C la4-da1u 0.012 screw fixing d09d95 2448 C la4-da2e 0.018 50127 C la4-da2g 0.018 110240 C la4-da2u 0.018 380415 C la4-da2n 0.018 varistors (peak limiting) (3) clip-on fixing and electrical d09d32 2448 2448 la4-de1e 0.012 connection. fitting of an input 50127 50127 la4-de1g 0.012 module is still possible. 110250 110250 la4-de1u 0.012 screw fixing d09d32 2448 2448 la4-de2e 0.018 50127 50127 la4-de2g 0.018 110250 110250 la4-de2u 0.018 d40d95 2448 C la4-de2e 0.018 50127 C la4-de2g 0.018 110250 C la4-de2u 0.018 d40d80 C 2448 la4-de3e 0.018 C 50127 la4-de3g 0.018 C 110250 la4-de3u 0.018 diodes (4) clip-on fixing and electrical d09d32 C 12250 la4-dc1u 0.012 connection. fitting of an input module is still possible. screw fixing d09d32 C 12250 la4-dc2u 0.018 d40d80 C 24250 la4-dc3u 0.018 bidirectional peak limiting diode (5) clip-on fixing and electrical d09d32 24 24 la4-db1b 0.012 connection. fitting of an input module is still possible. 72 72 la4-db1s 0.012 screw fixing d09d32 24 24 la4-db2b 0.018 72 72 la4-db2s 0.018 d40d95 24 C la4-db2b 0.018 72 C la4-db2s 0.018 d40d80 C 24 la4-db3b 0.018 C72 la4-db3s 0.018 (1) effective protection for circuits highly sensitive to high frequency interference. voltage limited to 3 uc max and oscillating frequency limited to 400 hz max. slight increase in drop-out time (1.2 to 2 times the normal time). (2) for satisfactory protection, a suppressor module must be fitted across the coil of each contactor (3) protection provided by limiting the transient voltage to 2 uc max. maximum reduction of transient voltage peaks. slight increase in drop-out time (1.1 to 1.5 times the normal time). (4) no overvoltage or oscillating frequency. increase in drop-out time (6 to 10 times the normal time). polarised component. (5) protection provided by limiting the transient voltage to 2 uc max. maximum reduction of transient voltage peaks. illustrations : page 1/40 http://www..net/ datasheet pdf - http://www..net/
1/42 te 1 lc1-d09, d12 lp1-d09, d12 lc1-d25 lp1-d25 la9-d92 la9-d93 lc1-d40, d50, d65 lp1-d40, d50, d65 lc1-d80, d95 lp1-d80 lc1-d18 lp1-d18 lc1-d32 lp1-d32 la9-d1260 la9-d1261 la9-d1262 la9-d1263 la9-d1860 la9-d2560 la9-d2561 la9-d2563 la9-d6567 la9-d8067 la9-d941 la9-d40961 la9-d40963 la9-d80962 la9-d80961 la9-d80963 la9-d3260 http://www..net/ datasheet pdf - http://www..net/
1/43 te 1 contactors d 3 and 4-pole contactors, reversing and changeover contactors accessories references accessories for main pole and control connections description for use on contactors sold in unit weight c lc1- a lp1- lots of reference kg connectors 4-pole d09, d12 d09, d12 1 la9-d1260 0.030 for cable 10 mm 2 sizes : 3-pole d18 d18 1 la9-d1860 0.035 25 mm 2 d2500, d32 d32 1 la9-d3260 0.040 4-pole d25 d25 1 la9-d2560 0.050 25 mm 2 links for 2 poles d09, d12 d09, d12 10 la9-d1261 0.012 parallel connection of d25 d25 10 la9-d2561 0.060 d40d65 d40d65 2 la9-d40961 0.021 d80, d95 d80 2 la9-d80961 0.060 3 poles d09, d12 d09, d12 10 la9-d1262 0.003 (star connection) d80, d95 d80 1 la9-d80962 0.080 4-pole d09, d12 d09, d12 2 la9-d1263 0.024 d25 d25 2 la9-d2563 0.017 d40d65 d40d65 2 la9-d40963 0.070 d80, d95 d80 2 la9-d80963 0.100 staggered coil connection C d40d80 10 la9-d09966 0.006 control circuit take-off C d40d65 10 la9-d6567 0.010 from main pole d80 10 la9-d8067 0.010 accessories for protection and marking description for use on sold in unit weight contactors add-on lots of reference c lc1- a lp1- blocks kg miniature fuse holder d09d95 d09d80 C 1 la9-d941 0.025 type 5 x 20 with 4 a - 250 v fuse legend holder d09d95 d09d80 la1-d 100 la9-d92 0.001 8 x 22 mm snap-in (4 contacts) la2-d, la3-d la6-dk legend holder C C la1-dn 100 la9-d90 0.001 8 x 17 mm snap-in (2 contacts) bag of 300 labels d09d95 d09d80 la1-d 1 la9-d93 0.001 (blank, self-adhesive) (4 contacts) 7 x 21 mm la2-d, la3-d la6-dk bag of 400 labels C C la1-dn 1 la9-d91 0.001 (blank, self-adhesive) 7 x 16 mm (2 contacts) sealing cover C C la2, la3-d 1 la9-d901 0.005 accessories for mounting adaptor for mounting on ' rail d09d32 d09d32 C 1 la9-d973 0.025 mounting plates for fixing on 2 ' rails d09d18 d09d18 C 10 dx1-ap25 0.065 (120 mm fixing centres) d25d32 d25d32 C 10 dx1-ap26 0.082 set of shims for fitting side-mounting blocks la8-dn on lc1-d40 to d95 1 la9-d511 0.020 illustrations : page 1/42 http://www..net/ datasheet pdf - http://www..net/
1/44 te 1 56 12,5 (la8) 12,5 (la8) 44 87(d i 1) 100(d i 2) 107(3)(df,dt) (dm,dr,dw,dl) la4 = = 115(3) 98 84 10 131(2)(la1) 141(la6-dk1) 150(1) (la2,la3,la6-dk2) 93 84 10 126(2)(la1) 136(la6-dk1) 145(1) (la2,la3,la6-dk2) 56 12,5 (la8) 12,5 (la8) 44 87(d i 1) 100(d i 2) 107(3)(df,dt) (dm,dr,dw,dl) la4 = = 115(3) contactors d 3 and 4-pole contactors, type lc1-d dimensions lc1-d09, d12 lc1-d18 lc1-d2500 (1) + 4 mm with lead sealing kit (1) + 4 mm with lead sealing kit (2) with 2 or 4 contacts (2) with 2 or 4 contacts (3) with or without combined use of a coil suppressor module (3) with or without combined use of a coil suppressor module la4-da1, de1 la4-da1, de1 lc1-d2510, d2501, d25004 lc1-d32 (1) + 4 mm with lead sealing kit (1) + 4 mm with lead sealing kit (2) with 2 or 4 contacts; 1 contact = 120 (la1-dn10 or dn01) (2) with 2 or 4 contacts; 1 contact = 125 (la1-dn10 or dn01) (3) with or without combined use of a coil suppressor module (3) with or without combined use of a coil suppressor module la4-da1, de1 la4-da1, de1 lc1-d40, d50, d65 lc1-d80, d95 (1) + 4 mm with lead sealing kit (1) + 4 mm with lead sealing kit (2) with 2 or 4 contacts; 1 contact = 139 (la1-dn10 or dn01) (2) with 2 or 4 contacts; 1 contact = 147 (la1-dn10 or dn01) (3) 75 : 3 poles, 85 : 4 poles (3) 85 : 3 poles, 96 : 4 poles (4) 125 : lc1-d ii 008 (4) 140 : lc1-d ii 008 minimum electrical clearance 45 12,5 (la8) 12,5 (la8) 44 la4 77(d i 1) 90(d i 2) 97(3)(df,dt) 105(3) (dm,dr,dw,dl) 74 93 10 113(2)(la1) 136(la6-dk1) 145(1) (la2,la3,la6-dk2) minimum electrical clearance 45 12,5 (la8) 12,5 (la8) 44 la4 77(d i 1) 90(d i 2) 97(3)(df,dt) 105(3) (dm,dr,dw,dl) 85 74 10 118(2)(la1) 128(la6-dk1) 137(1) (la2,la3,la6-dk2) minimum electrical clearance minimum electrical clearance 125(4) 12 153(2)(la1) 172(1)(la2,la3,la6-dk2) 127 135(d i 2) 142(df,dt) 150(dm,dr,dw,dl) (3) 12,5 (la8) 12,5 (la8) 44 la4 32 minimum electrical clearance 135(d i 2) 142(df,dt) 150(dm,dr,dw,dl) (3) 12,5 (la8) 12,5 (la8) 44 la4 28 114(4) 12 145(2)(la1) 164(1)(la2,la3,la6-dk2) 127 minimum electrical clearance references : pages 1/18 and 1/20 http://www..net/ datasheet pdf - http://www..net/
1/45 te 1 contactors d 3 and 4-pole contactors, type lp1-d dimensions lp1-d09, d12 lp1-d18 (1) + 4 mm with lead sealing kit (1) + 4 mm with lead sealing kit (2) with 2 or 4 contacts (2) with 2 or 4 contacts (3) with or without combined use of a coil suppressor module (3) with or without combined use of a coil suppressor module la4-dc1, de1. la4-dc1, de1. lp1-d25 lp1-d32 (1) + 4 mm with lead sealing kit (1) + 4 mm with lead sealing kit (2) with 2 or 4 contacts; 1 contact : 157 (la1-dn10 or dn01) (2) with 2 or 4 contacts; 1 contact : 162 (la1-dn10 or dn01) (3) with or without combined use of a coil suppressor module (3) with or without combined use of a coil suppressor module la4-dc1, de1. la4-dc1, de1. lp1-d40, d50, d65 lp1-d80 (1) + 4 mm with lead sealing kit (1) + 4 mm with lead sealing kit (2) with 2 or 4 contacts; 1 contact : 196 (la1-dn10 or dn01) (2) with 2 or 4 contacts; 1 contact : 204 (la1-dn10 or dn01) (3) 75 : 3 poles, 85 : 4 poles (3) 85 : 3 poles, 96 : 4 poles (4) 182 : lp1-d ii 008 (4) 196 : lp1-d ii 008 minimum electrical clearance minimum electrical clearance minimum electrical clearance minimum electrical clearance 115 10 148(2)(la1) 158(la6-dk1) 167(1)(la2,la3,la6-dk2) 74 45 12,5 (la8) 12,5 (la8) 44 la4 77(d i 1) 90(d i 2) 97(3)(df,dt) 105(3)(dm,dl) 120 10 153(2)(la1) 163(la6-dk1) 172(1)(la2,la3,la6-dk2) 74 45 12,5 (la8) 12,5 (la8) 44 la4 77(d i 1) 90(d i 2) 97(3)(df,dt) 105(3)(dm,dl) 135 10 168(2)(la1) 178(la6-dk1) 187(1)(la2,la3,la6-dk2) 84 56 12,5 (la8) 12,5 (la8) 44 87(d i 1) 100(d i 2) 107(3)(df,dt) 115(3)(dm ,dl) la4 = = 130 10 163(2)(la1) 173(la6-dk1) 182(1)(la2,la3,la6-dk2) 84 56 12,5 (la8) 12,5 (la8) 44 87(d i 1) 100(d i 2) 107(3)(df,dt) 115(3)(dm ,dl) la4 = = (3) 181(4) 12 210(2)(la1) 229(1)(la2,la3,la6-dk2) 127 la4-d i 3 (3) 171(4) 12 202(2)(la1) 221(1)(la2,la3,la6-dk2) 127 la4-d i 3 minimum electrical clearance minimum electrical clearance references : page 1/19 and 1/21 http://www..net/ datasheet pdf - http://www..net/
1/46 te 1 contactors d 3-pole reversing and 4-pole changeover contactors types lc2-d and lp2-d dimensions (1) lc2-d09 to d32 lp2-d09 to d32 2 x lc1-d09 to d32 2 x lp1-d09 to d32 lc2- or 2 x lc1- a b c e1(3p) e2(4p) g lp2- or 2 x lp1- a b c e1(3p)e2(4p) g d09, d12 105 74 84 7 6 95 d09, d12 105 74 119 7 6 95 d18 106 74 92 8 C 95 d18 106 74 127 8 C 95 d25 127 84 99 8 7 111 d25 127 84 136 8 7 111 d32 127 84 117 10 C 111 d32 127 84 154 10 C 111 c, e1 and e2 including cabling c, e1 and e2 including cabling lc2-d40 to d65 2 x lc1-d40 to d65 2 x lp1-d40 to d65 lc2- or 2 x lc1- (3 p) a b c e1 gg1 2 x lp1- (3 p) a b c e1 gg1 d40, d50, d65 165 127 142 5 50 90 d40, d50, d65 165 127 199 5 50 90 lc2- or 2 x lc1- (4 p) a b c e2 gg1 2 x lp1- (4 p) a b c e2 gg1 d40, d65 182 127 133 11 57 97 d40, d65 182 127 190 11 57 97 c, e1 and e2 including cabling c, e1 and e2 including cabling lc2-d80 and d95 2 x lc1-d80 and d95 2 x lp1-d80 lc2- or 2 x lc1- (3 p) a b c e1 gg1 2 x lp1- (3 p) a b c e1 gg1 d80, d95 182 127 158 13 57 96 d80 182 127 215 13 57 96 lc2- or 2 x lc1- (4 p) a b c e2 gg1 2 x lp1- (4 p) a b c e2 gg1 d80 207 127 158 20 71 111 d80 207 127 215 20 71 111 c, e1 and e2 including cabling c, e1 and e2 including cabling (1) dimensions with auxiliary contact blocks and add-on modules see pages 1/44 and 1/45. c b e1 e2 2x4,5 g a == 50/60 = = c b e1 e2 g1 == 6x6,5 40 a == g 40 100/110 8 13 references : pages 1/22 and 1/23 2x4,5 g a == 50/60 = = c b e1 e2 c b e1 e2 g1 == 6x6,5 40 a == g 40 100/110 8 13 b e1 e2 c g1 == 6x6,5 40 a == g 40 100/110 8 13 c b e1 e2 g1 == 6x6,5 40 a == g 40 100/110 8 13 http://www..net/ datasheet pdf - http://www..net/
1/47 te 1 contactors d 3 and 4-pole contactors, types lc1-d and lp1-d mounting lc1-d09 to d32 lc1-d40 to d95 panel mounted panel mounted lc1- d09 d12 d18 d25 d32 lc1- d40 d50 d65 d80 d95 c 80 80 85 93 98 c 114 114 114 125 125 g 3535354444 lp1-d09 to d32 lp1-d25 and d32 lp1-d40 to d80 panel mounted panel mounted lp1- d09 d12 d18 d25 d32 lp1- d40 d50 d65 d80 c 115 115 120 130 135 c 171 171 171 181 g 3535355050 lc1-d09 to d32 lc1-d40 to d95 on mounting rail am1-dp200 or am1-de200 on mounting rail am1-dl200 or dl201 (width 75 mm) on mounting rail am1-ed iii or am1-de200 (width 35 mm) lc1- d09 d12 d18 d25 d32 lc1- d40 d50 d65 d80 d95 b 7474748484 c (am1-dp200) 82 82 87 95 100 c (am1-dl200) 131 131 131 142 142 c (am1-de200) 90 90 95 103 108 c (am1-dl201/ 121 121 121 132 132 c (am1-ed iii or de200) 121 121 121 132 132 c 40 == 100/110 == 3x6,5 c 50 2x4,8 == g == 2x4,5 c 40 == 100/110 == 40 == 100/110 == 40 == 3x6,5 100/110 == 127 = = c = b = c c 50/60 == g == 2x4,5 2xm4 g == references : pages 1/18 to 1/21 http://www..net/ datasheet pdf - http://www..net/
1/48 te 1 contactors d 3 and 4-pole contactors, types lc1-d and lp1-d mounting lp1-d09 to d32 lp1-d40 to d80 on mounting rail am1-dp200 or am1-de200 on mounting rail am1-dl200 or am1-dl201 (width 75 mm) lp1- d09 d12 d18 d25 d32 lp1- d40 d50 d65 d80 c (am1-dp200) 117 117 122 132 137 c (am1-dl200) 188 188 188 198 c (am1-de200) 125 125 130 140 145 c (am1-dl201) 178 178 178 188 lc1, lp1-d09 to d32 lc1-d40 to d95, lp1-d40 to d80 on pre-slotted mounting plate am1-pa, pb, pc on pre-slotted mounting plate am1-pa, pb, pc lc1- d09 d12 d18 d25 d32 lc1- d40 d50 d65 d80 d95 c 80 80 85 93 98 c 114 114 114 125 125 g 35353544 44 lp1- d09 d12 d18 d25 d32 lp1- d40 d50 d65 d80 c 115 115 120 130 135 c 171 171 171 181 g 35 35 35 40 or 50 40 or 50 af1-ea6 40 110 c c 50 af1-ea4 g references : page 1/18 to 1/21 127 c c http://www..net/ datasheet pdf - http://www..net/
1/49 te 1 contactors d 3 and 4-pole contactors, types lc1-d and lp1-d mounting lc1, lp1-d09 to d32 lc1-d40 to d95, lp1-d40 to d80 on 1 mounting rail dz5-mb and clip-on mounting plate la9-d973 on 2 mounting rails dz5-mb on 120 mm centres d09 to d18 d25, d32 lc1- d09 d12 d18 d25 d32 lc1- d40 d50 d65 d80 d95 c 80 80 85 93 98 c 114 114 114 125 125 lp1- d09 d12 d18 d25 d32 lp1- d40 d50 d65 d80 c 115 115 120 130 135 c 171 171 171 181 lc1, lp1-d09 to d32 on 2 mounting rails dz5-mb on 120 mm centres on 2 mounting rails dz5-mb on 60 mm centres lc1- d09 d12 d18 d25 d32 lc1- d09 d12 d18 d25 d32 a 45 45 45 57 57 c 80 80 85 93 98 c 80808593 98 g 3535354444 (1) dx1-ap25 (lc1-d09 to d18), dx1-ap26 (lc1-d25 and d32) lp1- d09 d12 d18 d25 d32 lc1- d09 d12 d18 d25 d32 a 45 45 57 57 57 c 115 115 120 130 135 c 115 115 120 130 135 g 35 35 35 40 or 50 40 or 50 (1) dx1-ap25 (lp1-d09 to d18), dx1-ap26 (lp1-d25 and d32) 110 120 40 c 15 dz5-me5 c 15 50 60 dz5-me8 g 110 a 120 (1) c 27 dz5-me5 c 21 = 40 49 = 50 55 la9-d973 = 35 44 = 50 55 la9-d973 references : page 1/18 to 1/21 http://www..net/ datasheet pdf - http://www..net/
1/50 te 1 contactors d 3 and 4-pole contactors type lc1-d (9 to 95 a) a.c. coils references control average induc- reference (1) average induc- reference (1) weight circuit resis- tance resis- tance voltage tance. of tance. of uc at 20 c closed at 20 c closed 10% circuit 10 % circuit v w h w h kg for contactors lc1-d09, d12, d18, d2500 50 hz 60 hz 21 (2) 6.3 0.26 lx1-d2z5 4.98 0.21 lx1-d2z6 0.070 24 6.82 0.3 lx1-d2b5 5.45 0.25 lx1-d2b6 0.070 32 12.26 0.48 lx1-d2c5 C C C 0.070 42 21.32 0.93 lx1-d2d5 C C C 0.070 48 28.05 1.22 lx1-d2e5 22.09 1.02 lx1-d2e6 0.070 110 148.2 5.7 lx1-d2f5 116.6 4.5 lx1-d2f6 0.070 120 C C C 139.2 5.1 lx1-d2g6 0.070 127 192.5 7.5 lx1-d2g5 C C C 0.070 208 C C C 417.8 16.6 lx1-d2l6 0.070 220 C C C 490.2 18.5 lx1-d2m6 0.070 220/230 613.3 23 lx1-d2m5 C C C 0.070 230 649.7 25 lx1-d2p5 C C C 0.070 240 726.6 25 lx1-d2u5 587.4 21 lx1-d2u6 0.070 256 816 31 lx1-d2w5 C C C 0.070 277 C C C 781.5 30 lx1-d2w6 0.070 380 C C C 1486 55 lx1-d2q6 0.070 380/400 1848 67 lx1-d2q5 C C C 0.070 400 2069 68 lx1-d2v5 C C C 0.070 415 2219 78 lx1-d2n5 1826 69 lx1-d2n6 0.070 440 2549 82 lx1-d2r5 1892 71 lx1-d2r6 0.070 480 C C C 2304 85 lx1-d2t6 0.070 500 3285 107 lx1-d2s5 C C C 0.070 575 C C C 3432 119 lx1-d2s6 0.070 600 C C C 3678 135 lx1-d2x6 0.070 660 5631 190 lx1-d2y5 C C C 0.070 specifications average consumption at 20 c: - inrush (cos j = 0.75) 50 hz : 60 va, 60 hz : 70 va. - sealed (cos j = 0.3) 50 hz : 7 va, 60 hz : 7.5 va. operating range ( q 55 c) : 0.81.1 uc. 50/60 hz 21 (2) C C C 5.6 0.24 lx1-d2z7 0.070 24 C C C 6.19 0.26 lx1-d2b7 0.070 42 C C C 19.15 0.77 lx1-d2d7 0.070 48 CCC 251 lx1-d2e7 0.070 110 CCC 1305.5 lx1-d2f7 0.070 120 CCC 1596.7 lx1-d2g7 0.070 220/230 (3) C C C 539 22 lx1-d2m7 0.070 230 CCC 59521 lx1-d2p7 0.070 230/240 (4) C C C 645 25 lx1-d2u7 0.070 380/400 C C C 1580 60 lx1-d2q7 0.070 400 C C C 1810 64 lx1-d2v7 0.070 415 C C C 1938 74 lx1-d2n7 0.070 440 C C C 2242 79 lx1-d2r7 0.070 specifications average consumption at 20 c: - inrush (cos j = 0.75) 50/60 hz : 70 va to 50 hz. - sealed (cos j = 0.3) 50/60 hz : 8 va to 50 hz. operating range ( q 55 c) : 0.851.1 uc. (1) the last 2 digits of the reference represent the voltage code. (2) voltage for special coils fitted in contactors with serial timer modules, with 24 v supply. (3) this coil can be used on 240 v at 60 hz. (4) this coil can be used on 230/240 v at 50 hz and at 240 v only at 60 hz. c lx1-d2 ii http://www..net/ datasheet pdf - http://www..net/
1/51 te 1 contactors d 3 and 4-pole contactors type lc1-d (9 to 95 a) a.c. coils references control average induc- reference (1) average induc- reference (1) weight circuit resis- tance resis- tance voltage tance. of tance. of uc at 20 c closed at 20 c closed 10% circuit 10 % circuit v w h w h kg for contactors lc1-d25, d32 (except lc1-d2500) 50 hz 60 hz 21 (2) 3.5 0.23 lx1-d4z5 2.9 0.14 lx1-d4z6 0.070 24 4.5 0.25 lx1-d4b5 3.5 0.18 lx1-d4b6 0.070 32 8.6 0.45 lx1-d4c5 C C C 0.070 42 14.4 0.78 lx1-d4d5 C C C 0.070 48 18.6 1.1 lx1-d4e5 14.5 0.72 lx1-d4e6 0.070 110 105 5.4 lx1-d4f5 81 3.8 lx1-d4f6 0.070 120 C C C 98 4.5 lx1-d4g6 0.070 127 136 7.1 lx1-d4g5 C C C 0.070 208 C C C 272 14 lx1-d4l6 0.070 220 C C C 325 15 lx1-d4m6 0.070 220/230 431 21 lx1-d4m5 C C C 0.070 230 454 23 lx1-d4p5 C C C 0.070 240 526 25 lx1-d4u5 405 18 lx1-d4u6 0.070 256 565 29 lx1-d4w5 C C C 0.070 277 C C C 525 24 lx1-d4w6 0.070 380 C C C 1010 30 lx1-d4q6 0.070 380/400 1306 64 lx1-d4q5 C C C 0.070 400 1389 73 lx1-d4v5 C C C 0.070 415 1595 76 lx1-d4n5 C C C 0.070 440 1710 85 lx1-d4r5 1315 61 lx1-d4r6 0.070 480 C C C 1605 72 lx1-d4t6 0.070 500 2168 110 lx1-d4s5 C C C 0.070 575 C C C 2360 103 lx1-d4s6 0.070 600 C C C 2480 113 lx1-d4x6 0.070 660 3984 191 lx1-d4y5 C C C 0.070 specifications average consumption at 20 c: - inrush (cos j = 0.75) 50 hz : 90 va, 60 hz : 100 va. - sealed (cos j = 0.3) 50hz : 7.5 va, 60 hz : 8.5 va. operating range ( q 55 c) : 0.81.1 uc. 50/60 hz 21 (2) C C C 3.1 0.18 lx1-d4z7 0.085 24 C C C 4.3 0.23 lx1-d4b7 0.085 42 C C C 13.5 0.69 lx1-d4d7 0.085 48 C C C 16 0.92 lx1-d4e7 0.085 110 C C C 91 4.9 lx1-d4f7 0.085 120 C C C 107 5.5 lx1-d4g7 0.085 220/230 (3) C C C 367 16 lx1-d4m7 0.085 230 C C C 377 21 lx1-d4p7 0.085 230/240 (4) C C C 452 23 lx1-d4u7 0.085 380/400 C C C 1186 32 lx1-d4q7 0.085 400 C C C 1200 65 lx1-d4v7 0.085 415 C C C 1383 70 lx1-d4n7 0.085 440 C C C 1478 78 lx1-d4r7 0.085 specifications average consumption at 20 c: - inrush (cos j = 0.75) 50/60 hz : 100 va to 50 hz. - sealed (cos j = 0.3) 50/60 hz : 8.5 va to 50 hz. operating range ( q 55 c) : 0.851.1 uc. (1) the last 2 digits of the reference represent the voltage code. (2) voltage for special coils fitted in contactors with serial timer modules, with 24 v supply. (3) this coil can be used on 240 v at 60 hz. (4) this coil can be used on 230/240 v at 50 hz and at 240 v only at 60 hz. c lx1-d4 ii http://www..net/ datasheet pdf - http://www..net/
1/52 te 1 contactors d 3 and 4-pole contactors type lc1-d (9 to 95 a) a.c. coils references control average induc- reference (1) average induc- reference (1) weight circuit resis- tance resis- tance voltage tance. of tance. of uc at 20 c closed at 20 c closed 10% circuit 10 % circuit v w h w h kg for contactors lc1-d40, d50, d65, d80, d95 50 hz 60 hz 24 1.4 0.09 lx1-d6b5 1.05 0.06 lx1-d6b6 0.280 32 2.6 0.16 lx1-d6c5 C C C 0.280 42 4.4 0.27 lx1-d6d5 C C C 0.280 48 5.5 0.35 lx1-d6e5 4.2 0.23 lx1-d6e6 0.280 110 31 1.9 lx1-d6f5 22 1.2 lx1-d6f6 0.280 120 CCC 281.5 lx1-d6g6 0.280 127 41 2.4 lx1-d6g5 C C C 0.280 208 CCC 864.3 lx1-d6l6 0.280 220 CCC 984.8 lx1-d6m6 0.280 220/230 127 7.5 lx1-d6m5 C C C 0.280 230 133 8.1 lx1-d6p5 C C C 0.280 240 152 8.7 lx1-d6u5 120 5.7 lx1-d6u6 0.280 256 166 10 lx1-d6w5 C C C 0.280 277 CCC 1578 lx1-d6w6 0.280 380 CCC 30014 lx1-d6q6 0.280 380/400 381 22 lx1-d6q5 C C C 0.280 400 411 25 lx1-d6v5 C C C 0.280 415 463 26 lx1-d6n5 C C C 0.280 440 513 30 lx1-d6r5 392 19 lx1-d6r6 0.280 480 CCC 48023 lx1-d6t6 0.280 500 668 38 lx1-d6s5 C C C 0.280 575 CCC 67533 lx1-d6s6 0.280 600 CCC 77536 lx1-d6x6 0.280 660 1220 67 lx1-d6y5 C C C 0.280 specifications average consumption at 20 c: - inrush (cos j = 0.75) 50 hz : 200 va, 60 hz : 220 va. - sealed (cos j = 0.3) 50hz : 20 va, 60 hz : 22 va. operating range ( q 55 c) : 0.851.1 uc. 50/60 hz 24 C C C 1.22 0.08 lx1-d6b7 0.280 42 C C C 3.5 0.25 lx1-d6d7 0.280 48 C C C 5 0.32 lx1-d6e7 0.280 110 CCC 261.7 lx1-d6f7 0.280 120 CCC 322 lx1-d6g7 0.280 220/230 (2) C C C 102 6.7 lx1-d6m7 0.280 230 CCC 1157.7 lx1-d6p7 0.280 230/240 (3) C C C 131 8.3 lx1-d6u7 0.280 380/400 (4) C C C 310 20 lx1-d6q7 0.280 400 CCC 34923 lx1-d6v7 0.280 415 CCC 39024 lx1-d6n7 0.280 440 CCC 41027 lx1-d6r7 0.280 specifications average consumption at 20 c: - inrush (cos j = 0.75) 50 /60 hz : 245 va to 50 hz. - sealed (cos j = 0.3) 50/60 hz : 26 va to 50 hz. operating range ( q 55 c) : 0.851.1 uc. (1) the last 2 digits of the reference represent the voltage code. (2) for use on 230 v 50 hz, apply a multiplying factor of 0.6 to the mechanical life of the contactor. this coil can be used on 240 v at 60 hz. (3) this coil can be used on 220/240 v at 50 hz and at 240 v only at 60 hz. (4) for use on 400 v 50 hz, apply a multiplying factor of 0.6 to the mechanical life of the contactor. lx1-d6 ii c http://www..net/ datasheet pdf - http://www..net/
1/53 te 1 lx4-d2 ii lx4-d4 ii a contactors d 3 and 4-pole contactors type lp1-d (9 to 95 a) d.c. coils references control average resis- inductance voltage reference weight circuit voltage tance at 20 c of closed code uc 10 % circuit v w h kg for contactors lp1-d09, d12, d18 12 17 0.79 jd lx4-d2jd 0.175 21 (1) 45.4 2.16 zd lx4-d2zd 0.175 24 71 3.1 bd lx4-d2bd 0.175 36 149.7 7.1 cd lx4-d2cd 0.175 48 267 11.9 ed lx4-d2ed 0.175 60 422 19 nd lx4-d2nd 0.175 72 609 26 sd lx4-d2sd 0.175 110 1411 61.8 fd lx4-d2fd 0.175 125 1781 77.8 gd lx4-d2gd 0.175 220 5235 221 md lx4-d2md 0.175 250 6433 271 ud lx4-d2ud 0.175 440 19 785 793 rd lx4-d2rd 0.175 600 38 982 1393 xd lx4-d2xd 0.175 specifications average consumption : 9 w. operating range ( q 55 c) : 0.81.1 uc. control average resis- inductance voltage reference weight circuit voltage tance at 20 c of closed code uc 10 % circuit v w h kg for contactors lp1-d25, d32 12 13.3 0.73 jd lx4-d4jd 0.265 21 (1) 36.4 2.11 zd lx4-d4zd 0.265 24 53 2.92 bd lx4-d4bd 0.265 36 120.3 7.17 cd lx4-d4cd 0.265 48 211 11.3 ed lx4-d4ed 0.265 60 331 17.8 nd lx4-d4nd 0.265 72 473 27.5 sd lx4-d4sd 0.265 110 1122 63.6 fd lx4-d4fd 0.265 125 1431 81 gd lx4-d4gd 0.265 220 4461 237 md lx4-d4md 0.265 250 6044 338 ud lx4-d4ud 0.265 440 17 450 932 rd lx4-d4rd 0.265 600 33 610 1706 xd lx4-d4xd 0.265 specifications average consumption : 11 w. operating range ( q 55 c) : 0.81.1 uc. (1) voltage for special coils fitted in contactors with serial timer modules, with 24 v supply. http://www..net/ datasheet pdf - http://www..net/
1/54 te 1 a contactors d 3 and 4-pole contactors type lp1-d (9 to 95 a) d.c. coils references control average resis- inductance voltage reference weight circuit voltage tance at 20 c of closed code uc 10 % circuit v w h kg for contactors lp1-d40, d50, d65 12 7.1 0.44 jd lx4-d6jd 0.415 24 26.8 1.69 bd lx4-d6bd 0.415 36 58 3.55 cd lx4-d6cd 0.415 48 109 6.86 ed lx4-d6ed 0.415 60 173 10.9 nd lx4-d6nd 0.415 72 234 14.7 sd lx4-d6sd 0.415 110 560 35.28 fd lx4-d6fd 0.415 125 717 45.2 gd lx4-d6gd 0.415 220 2255 142 md lx4-d6md 0.415 250 2940 185 ud lx4-d6ud 0.415 440 9080 572 rd lx4-d6rd 0.415 600 17 230 1085 xd lx4-d6xd 0.415 specifications average consumption : 22 w. operating range : 0.851.1 uc. control average resis- inductance voltage reference weight circuit voltage tance at 20 c of closed code uc 10 % circuit v w h kg for contactors lp1-d80 12 6.6 0.46 jd lx4-d7jd 0.680 24 27 1.89 bd lx4-d7bd 0.680 36 57 4 cd lx4-d7cd 0.680 48 107 7.5 ed lx4-d7ed 0.680 60 170 11.9 nd lx4-d7nd 0.680 72 230 16.1 sd lx4-d7sd 0.680 110 564 39.5 fd lx4-d7fd 0.680 125 718 50.3 gd lx4-d7gd 0.680 220 2215 155 md lx4-d7md 0.680 250 2850 200 ud lx4-d7ud 0.680 440 9195 640 rd lx4-d7rd 0.680 600 17 425 1220 xd lx4-d7xd 0.680 specifications average consumption : 22 w. operating range : 0.851.1 uc. lx4-d6 ii lx4-d7 ii http://www..net/ datasheet pdf - http://www..net/
1/55 te 1 contactors d 3 and 4-pole contactors type lp1-d (9 to 95 a) wide range d.c. coils for specific applications references control average resis- inductance voltage reference weight circuit voltage tance at 20 c of closed code uc 10 % circuit v w h kg for contactors lp1-d09, d12, d18 12 15.6 0.71 jw lx4-d2jw 0.175 24 58.7 2.49 bw lx4-d2bw 0.175 36 122.6 5.3 cw lx4-d2cw 0.175 48 234 9.9 ew lx4-d2ew 0.175 72 530 21.4 sw lx4-d2sw 0.175 110 1105 44.4 fw lx4-d2fw 0.175 220 4593 185 mw lx4-d2mw 0.175 specifications average consumption : 11 w. operating range : 0.71.25 uc. coils with th treatment as standard. for contactors lp1-d25, d32 12 12.3 0.68 jw lx4-d4jw 0.265 24 49.2 2.71 bw lx4-d4bw 0.265 36 100.7 5.57 cw lx4-d4cw 0.265 48 199 10.8 ew lx4-d4ew 0.265 72 404 22.3 sw lx4-d4sw 0.265 110 944 51 fw lx4-d4fw 0.265 220 3953 208 mw lx4-d4mw 0.265 specifications average consumption : 13 w. operating range : 0.71.25 uc. coils with th treatment as standard. for contactors lp1-d40, d50, d65 12 6.8 0.45 jw lx4-d6jw 0.415 24 30 1.9 bw lx4-d6bw 0.415 36 53 3.5 cw lx4-d6cw 0.415 48 110 7.2 ew lx4-d6ew 0.415 72 215 14.2 sw lx4-d6sw 0.415 110 580 38.3 fw lx4-d6fw 0.415 220 2120 140 mw lx4-d6mw 0.415 specifications average consumption : 22 w. operating range : 0.751.2 uc. coils with th treatment as standard. for contactors lp1-d80 12 6.2 0.49 jw lx4-d7jw 0.680 24 23.5 1.75 bw lx4-d7bw 0.680 36 51.9 4.18 cw lx4-d7cw 0.680 48 94.2 7 ew lx4-d7ew 0.680 72 204 15.7 sw lx4-d7sw 0.680 110 483 36 fw lx4-d7fw 0.680 220 1922 144 mw lx4-d7mw 0.680 specifications average consumption : 23 w. operating range : 0.75...1.2 uc. coils with th treatment as standard. a lx4-d2 ii lx4-d4 ii lx4-d6 ii http://www..net/ datasheet pdf - http://www..net/


▲Up To Search▲   

 
Price & Availability of LC1-D0900XX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X